Skip to main content Skip to search Skip to main navigation
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2960 reviews

Retro Black

Our Retro Black is our interpretation of the popular ORB finish (Oil Rubbed Bronze). This is not just a simple black, but a very dark, antique finish with subtle bronze accents. This surface gives products a handcrafted feel and ensures the perfect vintage look without appearing outdated. Elegant, dark, and full of character....

Skip product gallery

Customers also bought

Skip product gallery

Customers also bought

Bathtub Faucet

  • High-quality mixer tap with ceramic cartridge (EN 817)
  • Made of solid brass with a premium finish
  • High-pressure faucet suitable for gas boilers, instantaneous water heaters, and all pressure systems
  • Includes diverter for hand shower
  • Backflow prevention compliant with DIN EN 1717
  • 1/2" connections
  • White ceramic insert
  • Activate the diverter by swiveling the spout

Note

Please note that the shower hose will be installed at the hose connection. The distance from the wall connections to the edge of the bathtub should be at least 13cm.

Shipping

  • Shipping weight: 2.1 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 05.06.2026, 10:40:11

[pdf] PGNX23-QP
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Armatur 11 Faucet 1
2 Dichtung 22 Seal 2
3 Blende 23 Escutcheon 2
4 S-Anschluss 24 S-Connector 2
Zertifikat unter: www.paulgurkesshop.deCertificate under: www.paulgurkesshop.de
LuftsprudlerAerator
Technical Data Ceramic Cartridge
Technische Daten KeramikkartuscheTechnical Data Ceramic Cartridge
KTW-Zulassung für TrinkwasserKTW approval for drinking water
Empfohlener Druck 1-5 BarRecommended pressure 1-5 Bar
Öffnungswinkel 25°Opening angle 25°
Maximale Temperatur 90°Maximum temperature 90°
Lebensdauer 70.000 Zyklen (EN 817)Lifespan 70,000 cycles (EN 817)
Operation
BedienungOperation
Regeln Sie die Intensität und die Temperatur des Wassers mit dem Griff wie in der Abbildung zu sehen. Durch schwenken des Auslaufs betätigen Sie den Umsteller.Adjust the intensity and temperature of the water with the handle as shown in the figure. By swiveling the spout, you operate the diverter.
Installation Steps
InstallationsschritteInstallation Steps
Umwickeln Sie die S-Anschlüsse mit Teflonband oder Hanf um diese abzudichten. Drehen Sie diese in die vorhandenen Anschlüsse der Wand. Montieren Sie die Blenden. Spülen Sie die Leitung mindestens zwei Minuten, bevor Sie die Armatur an die S-Anschlüsse anschließen.Wrap the S-connectors with Teflon tape or hemp to seal them. Screw them into the existing wall connections. Mount the escutcheons. Flush the pipe for at least two minutes before connecting the faucet to the S-connectors.
Care Instructions
PflegehinweiseCare Instructions
Farbige Oberflächen dürfen in keinem Fall mit scheuernden, ätzenden oder alkoholhaltigen Mitteln gereinigt werden. Spülen Sie das Produkt mit klarem Wasser ab und trocknen es mit einem Mikrofasertuch.Coloured surfaces must not be cleaned with abrasive, corrosive or alcohol-containing agents under any circumstances. Rinse the product with clear water and dry it with a microfibre cloth.
PaulGurkes Quality
PaulGurkes QualitätPaulGurkes Quality
Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. Each product undergoes a hand-picked quality control. If you are not satisfied with our products, please contact us.
[pdf] Analysebericht-PGNX23-QP
Analysis Report Header
Analysebericht PaulGurkes GmbH Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.Analysis Report PaulGurkes GmbH The sample was tested using X-ray fluorescence analysis and the following measurement result was obtained.
Report Information
Bericht-Nr.: #2019-1059 Herstellernummer: PGNX23-QP EAN: 4250914815221Report No.: #2019-1059 Manufacturer Number: PGNX23-QP EAN: 4250914815221
Element Composition
Element % ± 2σ Min Max Kupfer Cu 60,429 ± 0,779 57,000 60,000 Zink Zn 37,029 ± 0,657 37,000 41,500 Blei Pb 2,046 ± 0,237 1,600 2,200 Eisen Fe 0,226 ± 0,072 0,000 0,300 Zinn Sn 0,000 ± 0,277 0,000 0,300 Nickel Ni 0,000 ± 0,066 0,000 0,100 Aluminium Al 0,000 0,050Element % ± 2σ Min Max Copper Cu 60.429 ± 0.779 57.000 60.000 Zinc Zn 37.029 ± 0.657 37.000 41.500 Lead Pb 2.046 ± 0.237 1.600 2.200 Iron Fe 0.226 ± 0.072 0.000 0.300 Tin Sn 0.000 ± 0.277 0.000 0.300 Nickel Ni 0.000 ± 0.066 0.000 0.100 Aluminum Al 0.000 0.050
Suitability Confirmation
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.The proof of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided.
Material Compliance
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the DIN 50930-6 standard, which sets out statements regarding corrosion resistance.
Material Identification
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures
Olaf Manusch Geschäftsführer Hildesheim, Montag, 20. Mai 2019 Manus Marc Manusch Leitung Technik & QualitätswesenOlaf Manusch Managing Director Hildesheim, Monday, May 20, 2019 Manus Marc Manusch Head of Technology & Quality Assurance
Reference
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 20.05.2019).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on May 20, 2019).
[pdf] PGNX23_Anordnungsplan
Komponentendetails

[PDF] Allgemeine Pflegehinweise

Analysis Reports - PGNX23-QP - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. The sample was tested using X-ray fluorescence analysis with the following measurement result.
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. The tested material complies with the requirements of the German Federal Environmental Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list.
Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. According to the German Federal Environmental Agency, the material meets the standard DIN 50930-6, which describes corrosion resistance.
Material
CW617N (CuZn40Pb2) CW617N (CuZn40Pb2)
Report and Manufacturer Data
Bericht-Nr.: #2019-1059 Report No.: #2019-1059
Herstellernummer: PGNX23-QP Manufacturer Number: PGNX23-QP
EAN: 4250914815221 EAN: 4250914815221
Measurement Results
Analysenbericht: XL2-99147 Analysis Report: XL2-99147
Messung Nr.: 1059 Measurement No.: 1059
Modus: Legierungen Mode: Alloys
Messdauer: 6,6s Measurement Duration: 6.6s
Zeit: 20.05.2019 11:58:10 Time: 20.05.2019 11:58:10
Herstellernummer: pgnx23 - qp Manufacturer Number: pgnx23 - qp
Werkstoffvorschlag: CW617N_CuZn40Pb2 Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Element: Kupfer | Cu: 60,429 ± 0,779 | Min: 57,000 | Max: 60,000 Element: Copper | Cu: 60,429 ± 0,779 | Min: 57,000 | Max: 60,000
Element: Zink | Zn: 37,029 ± 0,657 | Min: 37,000 | Max: 41,500 Element: Zinc | Zn: 37,029 ± 0,657 | Min: 37,000 | Max: 41,500
Element: Blei | Pb: 2,046 ± 0,237 | Min: 1,600 | Max: 2,200 Element: Lead | Pb: 2,046 ± 0,237 | Min: 1,600 | Max: 2,200
Element: Eisen | Fe: 0,226 ± 0,072 | Min: 0,000 | Max: 0,300 Element: Iron | Fe: 0,226 ± 0,072 | Min: 0,000 | Max: 0,300
Element: Zinn | Sn: 0,000 ± 0,277 | Min: 0,000 | Max: 0,300 Element: Tin | Sn: 0,000 ± 0,277 | Min: 0,000 | Max: 0,300
Element: Nickel | Ni: 0,000 ± 0,066 | Min: 0,000 | Max: 0,100 Element: Nickel | Ni: 0,000 ± 0,066 | Min: 0,000 | Max: 0,100
Element: Aluminium | Al: 0,000 | Min: 0,050 Element: Aluminium | Al: 0,000 | Min: 0,050
Company Information
PaulGurkes GmbH PaulGurkes GmbH
Klingenbergstr. 12 Klingenbergstr. 12
31139 Hildesheim 31139 Hildesheim
Signatures and Date
Olaf Manusch, Geschäftsführer Olaf Manusch, Managing Director
Marc Manusch, Leitung Technik & Qualitätswesen Marc Manusch, Head of Engineering & Quality Management
Hildesheim, Montag, 20. Mai 2019 Hildesheim, Monday, May 20, 2019
Analysis Reports - PGNX23-QP - Version 1
Analysis Report
Sample Testing The sample was tested using X-ray fluorescence analysis and produced the following measurement result. This demonstrates suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001). The tested material complies with the requirements of the German Federal Environmental Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA Positive List. According to the German Federal Environmental Agency, the material meets the DIN 50930-6 standard, which specifies statements regarding corrosion resistance.
Material and Manufacturer Information
Material CW617N (CuZn40Pb2)
Report Number #2021-1240
Manufacturer Number PGNX23, PGMOON23, PGLUNA23
EAN 4250914806335, 4250914815498, 4250914813654
Company Information
Company PaulGurkes GmbH
Street Klingenbergstr. 12
City and Postal Code 31139 Hildesheim
Date Hildesheim, August 24, 2021
Measurement Results - Alloy Analysis
Analysis Report XL2-99147
Measurement Number 1240
Mode Alloys
Measurement Duration 6.7s
Time 24.08.2021 12:20:20
Manufacturer Number pgnx23
User Login Marc Manusch
Material Suggestion CW617N_CuZn40Pb2
Element Analysis
Element %
Measurement Uncertainty ± 2σ Min | Max
Copper Cu 59.975 ± 0.679 | 57.000 - 60.000
Zinc Zn 37.797 ± 0.591 | 37.000 - 41.500
Lead Pb 1.600 ± 0.195 | 1.600 - 2.200
Tin Sn 0.165 ± 0.109 | 0.000 - 0.300
Iron Fe 0.126 ± 0.054 | 0.000 - 0.300
Nickel Ni 0.088 ± 0.050 | 0.000 - 0.100
Aluminum Al 0.000 | Max 0.050
Ablaufgarnitur: Without waste set
Ausführung: Badarmatur
Material: Messing
Merkmal: Schwenkbarer Auslauf
Montageart: Aufputz Wandmontage
Variante: Einhebel Badewannenarmatur
Application: Cold and hot water supply
Application area: Bathtub
Article type: Tap
Colour: Black with copper
Connection: High pressure – pressure-resistant
Connection type: Connection dimension 150 mm
Finish: Glossy
Form: Rund
Serie: Mercury

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan