PaulGurkes Concealed Thermostat Retro Antique Brass 1-3 Outlets
Prices incl. VAT plus shipping costs
Dispatch by 10 November 2026 — Delivery time to Ireland: approx. 4–6 working days
Matching pieces
Will it fit your situation?
- Shipping weight4,0 kg
Technical data
- Colour
- Antique Brass
- Product number:
- PGTHR23W-B-BOX
- EAN:
- 4250914822533
- Shipping weight
- 4,0 kg
Reviews
2,969 verified shop reviews. This product has no review of its own yet — share your experience and help others plan their bathroom. We verify all reviews for authenticity.
Important Note
This base body can only be used with compatible PaulGurkes fittings.
Concealed Base Body
- Suitable for PaulGurkes fittings for PGBASIC
- Installation depth: 83-108 mm
- Made of solid brass casting
- 1/2" internal thread
- 4-way / 3-way / 2-way / 1-way
- Integrated spirit level for easy installation
- With NBR sealing sleeve for sealing within the composite
Installation Note
Connect the outlets according to the following specifications:
2-way fitting:
- Outlet top: overhead shower
- Outlet bottom: hand shower
3-way fitting:
- Outlet top: overhead shower
- Outlet bottom: hand shower
- Outlet right: bath spout
By connecting according to these specifications, you can easily use a different fitting.
Concealed Thermostatic Fitting
- Made of solid brass
- High-quality colour coating
- Suitable for 1-3 outlets, e.g. overhead shower and hand shower, bath spout
- Outlets are switched by turning the diverter
- Required base body: PGBASIC
- Long-life thermostatic cartridge
- Safety stop at 38 °C protects against accidentally excessive temperatures (scald protection)
Note
This item requires the following accessory:
- Base body - Manufacturer part number: PGBASIC - EAN: 4250914808827
Shipping
- Shipping weight: 3.98 Kg
- Shipping method: Parcel
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: info@paulgurkesshop.de
Last update: 6 Nov 2026, 13:22:34
Documents of the products included in the set
PGBASIC
Components
| |||
Installation Preparation
| |||
Installation Step 1 - Preparation
| |||
Installation Step 2 - Function Overview
| |||
Important Notes
| |||
Installation Step 2 - Testing
| |||
Installation Step 3 - Plastering
| |||
Important Legal Information
| |||
| Anschlussplan für PGBASIC | Connection diagram for PGBASIC |
| Montagehinweise | Installation instructions |
| Hinweise | Notes |
| Beachten Sie bei der Montage unbedingt die beiliegenden Installationsanleitungen. | When installing, be sure to observe the enclosed installation instructions. |
| Prüfen Sie die Montage unbedingt vor dem Fliesenlegen auf Korrektheit der Verbraucher! | Check the installation before tiling to ensure the consumer unit is correct! |
| Prüfen Sie die Montage des Grundkörpers in Hinsicht auf die zur Verwendung geplanten Komponenten. | Check the installation of the base unit with regard to the components planned for use. |
| Duschsystem 2-Wege | 2-way shower system |
| Duschsystem 3-Wege | 3-way shower system |
| Wasserfall Duschsystem | Waterfall shower system |
| Wannenset 2-Wege | 2-way tub set |
| Duschsystem 4-Wege | 4-way shower system |
| Wanneneinlauf | Tub inlet |
| Regendusche | Rain shower |
| Handbrause | Hand shower |
| Regenfall | Rainfall |
| geblockt | blocked |
| Wasserfall | Waterfall |
| Verbraucher 4 | Consumer 4 |
Flow rates for PGBASIC
| |||||||||||||||||||||||
Single-lever mixer (2-way)
| |||||||||||||||||||||||
Thermostatic valves (2-way + 3-way)
| |||||||||||||||||||||||
Select valves (2-way + 3-way)
| |||||||||||||||||||||||
Single-lever mixer (4-way)
| |||||||||||||||||||||||
Analysis Report
| |||||||||||||||
Introduction
| |||||||||||||||
Report Information
| |||||||||||||||
Material Composition
| |||||||||||||||
Suitability for Drinking Water
| |||||||||||||||
Material Compliance
| |||||||||||||||
Material Designation
| |||||||||||||||
Footer
| |||||||||||||||
| Components List | |
| Mixed |
Anschlussplan für PGBASIC / Connection diagram for PGBASIC
|
|||||||||||||||
Montagehinweise / Installation notes
|
|||||||||||||||
Hinweise / Notes
|
|||||||||||||||
Produktinformation / Product Information
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Komponenten / Components
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Installationsvorbereitung / Installation Preparation
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Installationsschritt - Vorbereitung / Installation Step 1 - Preparation
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Installationsschritt - Testen / Installation Step 2 - Testing
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Installationsschritt - Funktionsübersicht / Installation Step 2 - Function Overview
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3. Installationsschritt - Verputzen / Installation Step 3 - Plastering
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maintenance / Maintenance
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Wichtig / Important
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Components | |
| 1 8PM4X16 | 1 8PM4X16 |
| 2 81BE0000 | 2 81BE0000 |
| 3 80BE0000 | 3 80BE0000 |
| 4 8J128X18A | 4 8J128X18A |
| 5 81T23187 | 5 81T23187 |
| 6 85BK001 | 6 85BK001 |
| 7 82BE0000 | 7 82BE0000 |
| 8 8J103X16A | 8 8J103X16A |
| 9 8XJBE001 | 9 8XJBE001 |
| 10 84BE0000 | 10 84BE0000 |
| 11 8PM5X12 | 11 8PM5X12 |
| 12 85BE0000 | 12 85BE0000 |
| 13 103BE000 | 13 103BE000 |
| 14 88BM0000 | 14 88BM0000 |
| 15 8XJBE002 | 15 8XJBE002 |
| 16 83BE0000 | 16 83BE0000 |
| 17 8JT1A2D2 | 17 8JT1A2D2 |
| 18 8J22X24A | 18 8J22X24A |
| 19 8BS40X112 | 19 8BS40X112 |
| 20 8STG605 | 20 8STG605 |
| Temperature Ranges | |
| Max Mixed Cold Hot 108 | Max Mixed Cold Hot 108 |
| Min Mixed Mixed Mixed 80 | Min Mixed Mixed Mixed 80 |
| Manufacturer | |
| PaulGurkes GmbH | PaulGurkes GmbH |
| Flow Rates for PGBASIC | ||||||||||||||||||||||||||||||||||||||||||||||
| v1.0 | v1.0 | |||||||||||||||||||||||||||||||||||||||||||||
Thermostatic Mixers (2-way + 3-way)
|
||||||||||||||||||||||||||||||||||||||||||||||
Single-Lever Mixer (2-way)
|
||||||||||||||||||||||||||||||||||||||||||||||
Select Mixers (2-way + 3-way)
|
||||||||||||||||||||||||||||||||||||||||||||||
Single-Lever Mixer (4-way)
|
||||||||||||||||||||||||||||||||||||||||||||||
PGTHR23W-B
Components
| |||||||||||||||||||||||||||||||
Base Body Connection Plan
| |||||||||||||||||||||||||||||||
Installation steps
| |||||||||||||||||||||||||||||||
Regulate temperature
| |||||||||||||||||||||||||||||||
Switch outputs
| |||||||||||||||||||||||||||||||
Cleaning & Maintenance
| |||||||||||||||||||||||||||||||
PaulGurkes Quality
| |||||||||||||||||||||||||||||||
Product Name
|
|
Article Number
|
|
Manufacturer
|
[PDF] Allgemeine Pflegehinweise
| Colour: | Antique Brass |
|---|
Login