PaulGurkes Retro Thermostat for 1-3 Outlets in Black Nostalgia
€310.00*
Prices incl. VAT plus shipping costs
Dispatch by 18 June 2026 — Delivery time : 2-5 days
Built-in Thermostat Faucet
- Made of solid brass
- High-quality finish
- Suitable for 1-3 outlets, e.g., overhead and hand shower, bathtub filler
- Control outlets by turning the selector
- Required base unit PGBASIC
- Durable thermostat cartridge
- Safety lock at 38 °C prevents accidental scalding (burn protection)
Note
This item requires the following accessories:
- Base unit - Manufacturer number: PGBASIC - EAN: 4250914808827
Shipping
- Shipping weight: 2.02 Kg
- Shipping method: Paket
Product Safety Regulation
Manufacturer information:
Name des Herstellers: PaulGurkes GmbH
Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland
Elektronische Adresse: anfrage@paulgurkesshop.de
Letztes Update: 15.06.2026, 10:15:40
Components
| |||||||||||||||||||||||||||||||
Grundkörper Anschlussplan
| |||||||||||||||||||||||||||||||
Installationsschritte
| |||||||||||||||||||||||||||||||
Temperatur regeln
| |||||||||||||||||||||||||||||||
Ausgänge schalten
| |||||||||||||||||||||||||||||||
Säuberung & Wartung
| |||||||||||||||||||||||||||||||
PaulGurkes Qualität
| |||||||||||||||||||||||||||||||
[PDF] Allgemeine Pflegehinweise
| Analysis Report | |
| Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. | The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is thus demonstrated. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the standard DIN 50930-6, which provides information on corrosion resistance. |
| Material | |
| Werkstoff | CC575S (CuZn39Pb1Al) |
| Report Number and Manufacturer Number | |
| Report Number: | #2017-742 |
| Manufacturer Number: | PGTHR23W / PGTHR-3W |
| EAN: | 4250914808841 / 4250914810028 |
| Measurement Results | |
| Analysis Report: | XL2-99147 |
| Measurement Number: | 742 |
| Mode: | Alloys |
| Measurement Duration: | 14.5s |
| Time: | 02.12.2017 11:45:08 |
| Manufacturer Number: | pgthr23w |
| User Login: | Marc Manusch |
| Material Suggestion: | CC575S_CuZn39Pb1Al |
| Element Analysis | |
| Copper Cu: | 60.391 ± 0.428 (Min: 58.000 Max: 63.000) |
| Zinc Zn: | 38.093 ± 0.378 (Min: 33.500 Max: 41.500) |
| Lead Pb: | 1.196 ± 0.111 (Min: 0.200 Max: 1.400) |
| Iron Fe: | 0.125 ± 0.034 (Min: 0.000 Max: 0.300) |
| Tin Sn: | 0.097 ± 0.057 (Min: 0.000 Max: 0.500) |
| Nickel Ni: | 0.053 ± 0.030 (Min: 0.000 Max: 0.200) |
| Manganese Mn: | 0.000 ± 0.045 (Min: 0.000 Max: 0.050) |
| Silicon Si: | 0.000 (Min: 0.000 Max: 0.050) |
| Aluminium Al: | (Min: 0.300 Max: 0.900) |
| Signatories | |
| Managing Director: | Olaf Manusch |
| Head of Technical & Quality Management: | Marc Manusch |
| Address: | Klingenbergstr. 12, 31139 Hildesheim |
| Date and Location: | Hildesheim, December 2, 2017 |
Product Name
|
|
Article Number
|
|
Manufacturer
|
Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.
| Colour: | Black with copper |
|---|