Skip to main content Skip to search Skip to main navigation
Average rating with

Average rating of 4.9 out of 5 stars

(4.91/5.00) calculated out of 2966 reviews

Brass-Bronze

Our finish Brass-Bronze brings back the "Golden Age". It is not a simple gold, but a complex composition of warm bronze tones and dark "Black Nickel". Hand-brushed, it creates a vibrant texture with antique charm and visual depth. Thanks to a robust seal, this noble, nostalgic look remains durable and easy to maintain....

Concealed Installation Body

  • Compatible with PaulGurkes faucets for PGBASIC
  • Made of solid brass casting
  • 4-Way / 3-Way / 2-Way / 1-Way
  • Integrated level for easy installation
  • Includes sealing ring for secure connection

Installation Instructions

Connect consumers according to the following specifications:

2-Way Faucet:

  • Top outlet: overhead shower
  • Bottom outlet: hand shower

Concealed Thermostat Faucet

  • Made of solid brass
  • High-quality chrome finish
  • Suitable for 2 consumers, e.g., overhead and hand shower or bathtub spout
  • Control consumers by turning the diverter
  • Required base body PGBASIC
  • Durable thermostat cartridge
  • Safety lock at 38 °C protects against accidentally high temperatures (burn protection)

Overhead Shower

  • Made of solid brass
  • High-quality surface - antique brass / bronze
  • Ø 20 cm
  • Anti-lime nozzles
  • ECO flow restrictor max 10 L/min
  • 1/2" ball joint

Supply Arm for Overhead Showers

  • Nostalgic/Retro design
  • Made of solid brass
  • High-quality colored surface
  • Reach approximately 46 cm
  • Height approximately 9 cm
  • Pipe diameter 22 mm
  • Wall rose diameter 8.5 cm
  • 1/2" thread

Hand Shower

  • Made of solid brass
  • High-quality colored surface
  • Handle made of ceramic
  • 1 function
  • 20 cm long
  • Head Ø 7.2 cm
  • 1/2" connection
  • Compatible with all standard shower hoses

Shower Holder

  • Nostalgic design
  • Made of solid metal
  • High-quality colored surface
  • White ceramic insert
  • Inclination of the holder is adjustable (ball joint)
  • Only 1 drilling required
  • Compatible with all standard shower hoses with cone

Shower Hose

  • Flexible, durable hose made of stainless steel
  • Cone and hex nut made of brass, high-quality colored surface
  • Cone with rubber protection
  • Length 150 cm
  • 1/2" thread

Shipping

  • Shipping weight: 7.66 Kg
  • Shipping method: Paket

Product Safety Regulation

Manufacturer information:

Name des Herstellers: PaulGurkes GmbH

Postanschrift: Bördestr. 7, 31135 Hildesheim, Deutschland

Elektronische Adresse: anfrage@paulgurkesshop.de


Letztes Update: 09.06.2026, 07:20:01

Für dieses Produkt wurden noch keine Kundenbilder hochgeladen.

Weitere Kundenbilder zu im Set enthaltenen Produkten

PaulGurkes Concealed Body for Faucets up to 4-Way

PGBASIC

€103.00*

PaulGurkes Retro Thermostat 1-3 User Brass Bronze Nostalgia

PGTHR23W-B

€330.00*

PaulGurkes Vintage Wall Arm Retro Nostalgia Round Curved

PG9R-B

€88.00*

PaulGurkes Nostalgic Shower Head 20 cm

PGHPRETRO083-B

€186.00*

PaulGurkes Nostalgia Wall Connector Brass Bronze Hose Connection

PGWABNX-B

€82.00*

PaulGurkes Nostalgia Antique Shower Hose 150cm

PGHPS-B

€48.00*

PaulGurkes Shower Holder Bronze Nostalgia Ceramic Retro Country Style

PGMW5-B

€61.00*

PaulGurkes Retro Shower Head Handheld Antique Brass Bronze

PGHPBHS016-B

€83.00*

Documents of the products included in the set

PGBASIC

[pdf] PGBASIC-v1.2
Components
Nr. Komponente Anzahl 1 Wasserwaage 2 2 Pappkarte 1 3 Wasserwaagenrahmen 1 4 Schraube 6 5 Spülvorrichtung 1 6 Dichtung für Spülvorrichtung 1 7 Pin 2 8 Dichtmanschette 1 9 Grundkörper 1 10 Spreizbolzen 4 11 Innensechskantschlüssel 1 12 Verschlussstopfen 3 13 Montageanleitung 1 Zertifikat & Videoanleitung unter: 14 1 www.PaulGurkesShop.deNo. Component Quantity 1 Spirit level 2 2 Cardboard 1 3 Spirit level frame 1 4 Screw 6 5 Flushing device 1 6 Seal for flushing device 1 7 Pin 2 8 Sealing sleeve 1 9 Main body 1 10 Expansion bolt 4 11 Allen key 1 12 Sealing plugs 3 13 Installation instructions 1 Certificate & Video instructions under: 14 1 www.PaulGurkesShop.de
Installation Preparation
Installationsvorbereitung • Für die Installation der Box wird ein Loch von mindestens 200mm x 220mm benötigt. • Die Einbautiefe beträgt 83mm - 108mm. • Bereiten Sie die Leitungen wie in der folgenden Abbildung vor. • Der Druck sollte 0,5 - 10 Bar nicht überschreiten. Empfohlener Druck ist 5 Bar.Installation preparation • A hole of at least 200mm x 220mm is required to install the box. • The installation depth is 83mm - 108mm. • Prepare the pipes as shown in the following illustration. • The pressure should not exceed 0.5 - 10 bar. Recommended pressure is 5 bar.
Installation Step 1 - Preparation
1. Installationsschritt - Vorbereitung • Merke: Die Box ist standardmäßig für vier Ausgänge konfiguriert. Für eine Nutzung von einem / zwei oder drei Ausgängen blockieren Sie die Ausgänge wie im unteren Schaubild abgebildet. • Bohren Sie die Installationslöcher, wie in der Abbildung zu sehen ist. • Platzieren Sie nun die Box in dem Installationsloch und fixieren Sie diese mit den Spreizschrauben. • Für die Installation in eine Ständerwand montieren Sie die Box wie im oberen Schaubild. • Überprüfen Sie die Festigkeit der Schrauben. • Schließen Sie die Warmwasser und Kaltwasser Leitungen an. • Schließen Sie die Verbraucher nach dem unteren Schaubild an.1. Installation step - Preparation • Note: The box is configured by default for four outputs. For use with one / two or three outputs, block the outputs as shown in the diagram below. • Drill the installation holes as shown in the illustration. • Now place the box in the installation hole and fix it with the expansion bolts. • For installation in a stud wall, mount the box as shown in the diagram above. • Check the tightness of the screws. • Connect the hot and cold water pipes. • Connect the consumers according to the diagram below.
Installation Step 2 - Function Overview
2. Installationsschritt - Funktionsübersicht2. Installation step - Function overview
Important Notes
WICHTIG! • Der untere Ausgang wird zuerst angesteuert (bei 2-Wege Armaturen). • Überprüfen Sie die Richtigkeit der Ausgänge an den Verbrauchern vor dem Verputzen in Abhängigkeit der zur Verwendung geplanten Armatur!IMPORTANT! • The lower outlet is activated first (for 2-way fittings). • Check that the outlets are correctly connected to the consumers before plastering, depending on the fitting planned for use!
Installation Step 2 - Testing
2. Installationsschritt - Testen • Öffnen Sie die Wasserleitungen und prüfen Sie die Montage auf Dichtheit. • Demontieren Sie die Spülvorrichtung und entfernen Sie die Gummistopfen aus dem Grundkörper. • Montieren Sie die Verschlusskappe erneut und spülen Sie 3 Minuten die Leitungen, um diese von Verschmutzungen zu säubern.2. Installation step - Testing • Open the water pipes and check the installation for leaks. • Disassemble the flushing device and remove the rubber plugs from the main body. • Reassemble the sealing cap and flush the pipes for 3 minutes to clean them of dirt.
Installation Step 3 - Plastering
3. Installationsschritt - Verputzen • Wenn die Installation die Dichtheitsprüfung bestanden hat, verputzen Sie die Montage. • Kontrollieren Sie die Position der Box. • Dichten Sie nun die Box im Verbund ab, bevor Sie die Fließen an die Wand bringen. • Verfliesen Sie die Installation. • Schneiden Sie das überstehende Material der Box ab. • Dichten Sie zuletzt die Schnittkante ab. • Die Installation ist abgeschlossen. Montieren Sie nun die Armatur.3. Installation step - Plastering • Once the installation has passed the leak test, plaster the installation. • Check the position of the box. • Now seal the box in the composite before attaching the tiles to the wall. • Tile the installation. • Cut off any protruding material from the box. • Finally, seal the cut edge. • The installation is complete. Now install the fitting.
Important Legal Information
WICHTIG! • Beachten Sie bei der Installation alle erforderlichen gesetzlichen und nationalen Bestimmungen (anerkannte Regeln der Technik) und halten Sie diese ein.IMPORTANT! • During installation, observe and comply with all necessary legal and national regulations (recognized rules of technology).
[pdf] PGBASIC-Anschlussplan-v1.0
Anschlussplan für PGBASICConnection diagram for PGBASIC
MontagehinweiseInstallation instructions
HinweiseNotes
Beachten Sie bei der Montage unbedingt die beiliegenden Installationsanleitungen.When installing, be sure to observe the enclosed installation instructions.
Prüfen Sie die Montage unbedingt vor dem Fliesenlegen auf Korrektheit der Verbraucher!Check the installation before tiling to ensure the consumer unit is correct!
Prüfen Sie die Montage des Grundkörpers in Hinsicht auf die zur Verwendung geplanten Komponenten.Check the installation of the base unit with regard to the components planned for use.
Duschsystem 2-Wege2-way shower system
Duschsystem 3-Wege3-way shower system
Wasserfall DuschsystemWaterfall shower system
Wannenset 2-Wege2-way tub set
Duschsystem 4-Wege4-way shower system
WanneneinlaufTub inlet
RegenduscheRain shower
HandbrauseHand shower
RegenfallRainfall
geblocktblocked
WasserfallWaterfall
Verbraucher 4Consumer 4
[pdf] PGBASIC-Durchflussmengen
Flow rates for PGBASIC
Durchflussmengen für PGBASICFlow rates for PGBASIC
Durchflussmengen in l/minFlow rates in l/min
Single-lever mixer (2-way)
Einhandmischer (2-Wege)Single-lever mixer (2-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 9,5 10,3 8,8B 9.5 10.3 8.8
D 9,6 10,6 8,9D 9.6 10.6 8.9
B 16,7 18,3 15,4B 16.7 18.3 15.4
D 17 18,7 15,7D 17 18.7 15.7
Thermostatic valves (2-way + 3-way)
Thermostatarmaturen (2-Wege + 3-Wege)Thermostatic valves (2-way + 3-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 8 12,2 9,3B 8 12.2 9.3
C 8 12 9,2C 8 12 9.2
D 7,8 12,5 9D 7.8 12.5 9
B 14,2 22,3 16,5B 14.2 22.3 16.5
C 14 21,8 16,3C 14 21.8 16.3
D 14,6 22,5 16,6D 14.6 22.5 16.6
Select valves (2-way + 3-way)
Selectarmaturen (2-Wege + 3-Wege)Select valves (2-way + 3-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
B 14,6 17,4 14,6B 14.6 17.4 14.6
C 16,5 20,2 16,9C 16.5 20.2 16.9
D 15,6 18,6 15,9D 15.6 18.6 15.9
Single-lever mixer (4-way)
Einhandmischer (4-Wege)Single-lever mixer (4-way)
AusgangOutlet
Warm Gemisch KaltWarm Mixed Cold
A 9,3 10,3 9,8A 9.3 10.3 9.8
B 9,2 10,2 9,7B 9.2 10.2 9.7
C 9,4 10,4 9,8C 9.4 10.4 9.8
D 9,7 10,7 10D 9.7 10.7 10
A 16,8 18,7 17,8A 16.8 18.7 17.8
B 16,6 18,5 17,6B 16.6 18.5 17.6
C 16,8 18,7 17,8C 16.8 18.7 17.8
D 17,3 19,5 18,3D 17.3 19.5 18.3
[pdf] Analysebericht-PGBASIC
Analysis Report
AnalyseberichtAnalysis Report
Introduction
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested by X-ray fluorescence analysis and yielded the following measurement result.
Report Information
Bericht-Nr.: #2017-749Report No.: #2017-749
Herstellernummer: PGBASICManufacturer Number: PGBASIC
Material Composition
Kupfer Cu 58,679 ± 0,573 57,000 60,000Copper Cu 58.679 ± 0.573 57.000 60.000
Zink Zn 39,262 ± 0,512 37,000 41,500Zinc Zn 39.262 ± 0.512 37.000 41.500
Blei Pb 1,727 ± 0,173 1,600 2,200Lead Pb 1.727 ± 0.173 1.600 2.200
Eisen Fe 0,153 ± 0,049 0,000 0,300Iron Fe 0.153 ± 0.049 0.000 0.300
Zinn Sn 0,114 ± 0,074 0,000 0,300Tin Sn 0.114 ± 0.074 0.000 0.300
Nickel Ni 0,064 ± 0,041 0,000 0,100Nickel Ni 0.064 ± 0.041 0.000 0.100
Aluminium Al 0,000 0,050Aluminum Al 0.000 0.050
Suitability for Drinking Water
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht.Proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
Material Compliance
Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The tested material complies with the requirements of the German Federal Environment Agency regarding the "Assessment principles for metallic materials in contact with drinking water"- UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which provides information regarding corrosion resistance.
Material Designation
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Footer
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 03.04.2017).German Federal Environment Agency: "Assessment basis for metallic materials in contact with drinking water", (accessed on 03.04.2017).
[pdf] PGBASIC_Anordnungsplan
Components List
Mixed
Product Manuals - PGBASIC - Version 1
Connection Diagram for PGBASIC
Connection Diagram for PGBASIC v1.0 of 1
Installation Instructions
Installation Instructions Be sure to follow the included installation instructions during assembly.
Check the assembly carefully before tiling to ensure correct placement of the consumers!
Check the assembly of the basic body with regard to the components planned for use.
Notes
Notes Hand shower blocked blocked
Rain shower hand shower blocked
Rain shower bathtub inlet hand shower blocked blocked
Bathtub inlet rain waterfall hand shower blocked
Shower system 3-way
Shower system 2-way bathtub set 2-way waterfall
Shower system shower system 4-way hand shower rain shower bathtub inlet consumer 4
Product Manuals - PGBASIC - Version 1.2
Analysis Reports - PGBASIC - Version 1
Product Information
Produktname: PaulGurkes Unterputz Grundkörper für Armaturen bis 4-Wege Product Name: PaulGurkes In-Wall Rough-In Body for Fixtures up to 4-Way
Artikelnummer: PGBASIC Article Number: PGBASIC
Version: v1.2 Version: v1.2
Components
1 - Wasserwaage - 2 1 - Spirit Level - 2
2 - Pappkarte - 1 2 - Cardboard Card - 1
3 - Wasserwaagenrahmen - 1 3 - Spirit Level Frame - 1
4 - Schraube - 6 4 - Screw - 6
5 - Spülvorrichtung - 1 5 - Flush Device - 1
6 - Dichtung für Spülvorrichtung - 1 6 - Seal for Flush Device - 1
7 - Pin - 2 7 - Pin - 2
8 - Dichtmanschette - 1 8 - Sealing Cuff - 1
9 - Grundkörper - 1 9 - Rough-In Body - 1
10 - Spreizbolzen - 4 10 - Expansion Bolt - 4
11 - Innensechskantschlüssel - 1 11 - Hex Key - 1
12 - Verschlussstopfen - 3 12 - Closure Plug - 3
13 - Montageanleitung - 1 13 - Assembly Instructions - 1
14 - Zertifikat & Videoanleitung unter: www.PaulGurkesShop.de 14 - Certificate & Video Instructions at: www.PaulGurkesShop.de
Installation Preparation
Für die Installation der Box wird ein Loch von mindestens 200mm x 220mm benötigt. A hole of at least 200 mm x 220 mm is required for box installation.
Die Einbautiefe beträgt 83mm - 108mm. Installation depth is 83 mm - 108 mm.
Bereiten Sie die Leitungen wie in der folgenden Abbildung vor. Prepare the lines as shown in the following figure.
Der Druck sollte 0,5 - 10 Bar nicht überschreiten. Empfohlener Druck ist 5 Bar. Pressure should not exceed 0.5 - 10 bar. Recommended pressure is 5 bar.
Step 1 of Installation - Preparation
Die Box ist standardmäßig für vier Ausgänge konfiguriert. Für eine Nutzung von einem / zwei oder drei Ausgängen blockieren Sie die Ausgänge wie im unteren Schaubild abgebildet. The box is configured by default for four outlets. For use of one, two, or three outlets, block the outlets as shown in the diagram below.
Bohren Sie die Installationslöcher, wie in der Abbildung zu sehen ist. Drill the installation holes as shown in the illustration.
Platzieren Sie nun die Box in dem Installationsloch und fixieren Sie diese mit den Spreizschrauben. Now place the box in the installation hole and secure it with the expansion bolts.
Für die Installation in eine Ständerwand montieren Sie die Box wie im oberen Schaubild. For installation in a stud wall, mount the box as shown in the upper diagram.
Überprüfen Sie die Festigkeit der Schrauben. Check the tightness of the screws.
Analysis Report
Analysebericht The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability of the product for use in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus proven. The tested material meets the requirements of the German Federal Environment Agency (UBA) concerning "Assessment bases for metallic materials in contact with drinking water" – UBA positive list. The material complies with DIN 50930-6 standard according to the German Federal Environment Agency, which provides statements regarding corrosion resistance.
Material and Designation
Material: CW617N (CuZn40Pb2)
Manufacturer Number: PGBASIC
EAN: 4250914808827
Report No.: #2017-749
Measurement Results
Analysis Report: XL2-99147
Measurement No.: 749
Mode: Alloys
Measurement Duration: 8.6s
Time: 02.12.2017 11:48:23
Manufacturer Number: pgbasic
Material Suggestion: CW617N_CuZn40Pb2
Element Analysis
Element % ± 2σ Min Max
Copper Cu 58.679 ± 0.573 57.000 60.000
Zinc Zn 39.262 ± 0.512 37.000 41.500
Lead Pb 1.727 ± 0.173 1.600 2.200
Iron Fe 0.153 ± 0.049 0.000 0.300
Tin Sn 0.114 ± 0.074 0.000 0.300
Nickel Ni 0.064 ± 0.041 0.000 0.100
Aluminum Al 0.000 0.050
Signatory and Contact
Signatory: Olaf Manusch, Managing Director
Engineering and Quality Management: Marc Manusch, Engineering and Quality Management
Company: PaulGurkes GmbH, Klingenbergstr. 12, 31139 Hildesheim
User Login: Marc Manusch
Date: Hildesheim, December 2, 2017
Layout Plans - PGBASIC - Version 1
Components
1 8PM4X16 1 8PM4X16
2 81BE0000 2 81BE0000
3 80BE0000 3 80BE0000
4 8J128X18A 4 8J128X18A
5 81T23187 5 81T23187
6 85BK001 6 85BK001
7 82BE0000 7 82BE0000
8 8J103X16A 8 8J103X16A
9 8XJBE001 9 8XJBE001
10 84BE0000 10 84BE0000
11 8PM5X12 11 8PM5X12
12 85BE0000 12 85BE0000
13 103BE000 13 103BE000
14 88BM0000 14 88BM0000
15 8XJBE002 15 8XJBE002
16 83BE0000 16 83BE0000
17 8JT1A2D2 17 8JT1A2D2
18 8J22X24A 18 8J22X24A
19 8BS40X112 19 8BS40X112
20 8STG605 20 8STG605
Temperature Ranges
Max Mixed Cold Hot 108 Max Mixed Cold Hot 108
Min Mixed Mixed Mixed 80 Min Mixed Mixed Mixed 80
Manufacturer
PaulGurkes GmbH PaulGurkes GmbH
Miscellaneous Documents - PGBASIC - Version 1
Flow Rates for PGBASIC
v1.0 v1.0
Thermostatic Mixers (2-way + 3-way)
Bar Outlet Hot Water Mixed Cold Water
1 B 8 12,2 9,3
1 C 8 12 9,2
1 D 7,8 12,5 9
3 B 14,2 22,3 16,5
3 C 14 21,8 16,3
3 D 14,6 22,5 16,6
Single-Lever Mixer (2-way)
Bar Outlet Hot Water Mixed Cold Water
1 B 9,5 10,3 8,8
1 D 9,6 10,6 8,9
3 B 16,7 18,3 15,4
3 D 17 18,7 15,7
Select Mixers (2-way + 3-way)
Bar Outlet Hot Water Mixed Cold Water
3 B 14,6 17,4 14,6
3 C 16,5 20,2 16,9
3 D 15,6 18,6 15,9
Single-Lever Mixer (4-way)
Bar Outlet Hot Water Mixed Cold Water
1 A 9,3 10,3 9,8
1 B 9,2 10,2 9,7
1 C 9,4 10,4 9,8
1 D 9,7 10,7 10
3 A 16,8 18,7 17,8
3 B 16,6 18,5 17,6
3 C 16,8 18,7 17,8
3 D 17,3 19,5 18,3

PGTHR23W-B

[pdf] PGTHR23W-B
Components
Nr. Komponente AnzahlNo. Component Quantity
1 Kappe 11 Cap 1
2 Schraube 22 Screw 2
3 Griff 13 Handle 1
5 Blende 15 Escutcheon 1
6 Dichtung 26 Seal 2
7 Schraube 47 Screw 4
8 Fliesenspiegel 18 Tile mirror 1
9 Dichtung 19 Seal 1
10 Armatur 110 Fitting 1
11 Dichtungen 711 Seals 7
12 Schlüssel * 112 Key * 1
13 Anleitung 113 Instructions 1
Zertifikat unter: www.paulgurkesshop.de 1Certificate under: www.paulgurkesshop.de 1
15 Schlüssel 215 Key 2
Base Body Connection Plan
Grundkörper AnschlussplanBase Body Connection Plan
• Die Armatur steuert die Ausgänge B + C + D an. • Der Ausgang A wird nicht angesteuert. • Nicht benötigte Ausgänge müssen druckfest verschlossen sein. • Die Armatur kann 1-3 Verbraucher ansteuern.• The fitting controls outputs B + C + D. • Output A is not controlled. • Unused outputs must be sealed pressure-tight. • The fitting can control 1-3 consumers.
Installation steps
InstallationsschritteInstallation steps
• Nach der Installation der Unterputz-Box und Prüfung auf Dichtheit ist das Wasser abzustellen. • Entfernen Sie den Schutz der Box. Montieren Sie die Armatur wie im zweiten Schaubild. • Ziehen Sie die Schrauben fest an, vergessen Sie die O-Ringe nicht. • Montieren Sie nun die Abdeckungen wie im dritten Bild. Justieren Sie die Abdeckung, bevor Sie diese fixieren. • Installieren Sie die Blende der Armatur wie im letzten Installationsbild. • Montieren Sie nun den Rest der Armatur.• After installing the in-wall box and checking for leaks, turn off the water. • Remove the protection from the box. Assemble the fitting as shown in the second diagram. • Tighten the screws firmly, do not forget the O-rings. • Now mount the covers as shown in the third picture. Adjust the cover before fixing it. • Install the escutcheon of the fitting as shown in the last installation picture. • Now assemble the rest of the fitting.
Regulate temperature
Temperatur regelnRegulate temperature
• Regeln Sie die Temperatur wie im unteren Schaubild.• Regulate the temperature as shown in the diagram below.
Switch outputs
Ausgänge schaltenSwitch outputs
• Schalten Sie die Ausgänge der Armatur wie im folgenden Schaubild.• Switch the outputs of the fitting as shown in the following diagram.
Cleaning & Maintenance
Säuberung & WartungCleaning & Maintenance
Um eine gleichbleibende Qualität zu gewährleisten, ist folgendes zu beachten: • Mit sauberem Wasser abspülen & mit Mikrofasertuch trocknen. • Schmutz nur mit milden Reinigungsmitteln entfernen. • Benutzen Sie keine Scheuermilch, Polierpaste, Papiertücher, etc. • Benutzen Sie keine säurehaltigen Reinigungsmittel oder Seife.To ensure consistent quality, please note the following: • Rinse with clean water & dry with a microfiber cloth. • Remove dirt only with mild detergents. • Do not use scouring milk, polishing paste, paper towels, etc. • Do not use acidic cleaning agents or soap.
PaulGurkes Quality
PaulGurkes QualitätPaulGurkes Quality
• Herzlichen Glückwunsch zum Kauf Ihres PaulGurkes Qualitätsproduktes. Unsere Produkte sind technisch ausgereift und unter Verwendung hochwertiger Materialien gefertigt. • Jedes Produkt unterzieht sich einer handverlesenen Qualitätskontrolle. • Sollten Sie mit unseren Produkten nicht zufrieden sein, kontaktieren Sie uns.• Congratulations on purchasing your PaulGurkes quality product. Our products are technically sophisticated and manufactured using high-quality materials. • Each product undergoes a hand-picked quality control. • If you are not satisfied with our products, please contact us.
Wir behalten uns das Recht vor, Aktualisierungen, Änderungen oder Ergänzungen an den bereitgestellten Informationen und Daten vorzunehmen.We reserve the right to make updates, changes or additions to the information and data provided.
Analysis Reports - PGTHR23W-B - Version 1
Analysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht. Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser"- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt. The sample was tested using X-ray fluorescence analysis and produced the following measurement result. The suitability for drinking water installations in accordance with the Drinking Water Ordinance (TrinkwV 2001) is thus demonstrated. The tested material complies with the requirements of the German Federal Environment Agency regarding "Assessment criteria for metallic materials in contact with drinking water" - UBA positive list. According to the German Federal Environment Agency, the material meets the standard DIN 50930-6, which provides information on corrosion resistance.
Material
Werkstoff CC575S (CuZn39Pb1Al)
Report Number and Manufacturer Number
Report Number: #2017-742
Manufacturer Number: PGTHR23W / PGTHR-3W
EAN: 4250914808841 / 4250914810028
Measurement Results
Analysis Report: XL2-99147
Measurement Number: 742
Mode: Alloys
Measurement Duration: 14.5s
Time: 02.12.2017 11:45:08
Manufacturer Number: pgthr23w
User Login: Marc Manusch
Material Suggestion: CC575S_CuZn39Pb1Al
Element Analysis
Copper Cu: 60.391 ± 0.428 (Min: 58.000 Max: 63.000)
Zinc Zn: 38.093 ± 0.378 (Min: 33.500 Max: 41.500)
Lead Pb: 1.196 ± 0.111 (Min: 0.200 Max: 1.400)
Iron Fe: 0.125 ± 0.034 (Min: 0.000 Max: 0.300)
Tin Sn: 0.097 ± 0.057 (Min: 0.000 Max: 0.500)
Nickel Ni: 0.053 ± 0.030 (Min: 0.000 Max: 0.200)
Manganese Mn: 0.000 ± 0.045 (Min: 0.000 Max: 0.050)
Silicon Si: 0.000 (Min: 0.000 Max: 0.050)
Aluminium Al: (Min: 0.300 Max: 0.900)
Signatories
Managing Director: Olaf Manusch
Head of Technical & Quality Management: Marc Manusch
Address: Klingenbergstr. 12, 31139 Hildesheim
Date and Location: Hildesheim, December 2, 2017
Layout Plans - PGTHR23W-B - Version 1
Product Name
PaulGurkes 2-Way In-Wall Thermostatic Valve Fitting for Base Body PGBASIC
Article Number
PGTHR23W
Manufacturer
PaulGurkes GmbH

PGWABNX-B

[pdf] Analysebericht-PGWABNX-B
Analysis Report Header
AnalyseberichtAnalysis Report
Die Probe wurde mittels Röntgenfluoreszenzanalyse getestet und hat folgendes Messergebnis erbracht.The sample was tested using X-ray fluorescence analysis and yielded the following measurement result.
Bericht-Nr.: #2022-1307 Herstellernummer: PGWABNX-B EAN: 4250914818451Report No.: #2022-1307 Manufacturer No.: PGWABNX-B EAN: 4250914818451
Component: Connection Thread
Bauteil: AnschlussgewindeComponent: Connection Thread
Element % + 2σ Min Max Kupfer Cu 58,919 ± 0,717 57,000 60,000 Zink Zn 38,828 ± 0,629 37,000 41,500 Blei Pb 2,115 ± 0,229 1,600 2,200 Eisen Fe 0,136 ± 0,057 0,000 0,300 Zinn Sn 0,000 ± 0,137 0,000 0,300 Nickel Ni 0,000 ± 0,065 0,000 0,100 Aluminium Al 0,000 0,050Element % + 2σ Min Max Copper Cu 58.919 ± 0.717 57.000 60.000 Zinc Zn 38.828 ± 0.629 37.000 41.500 Lead Pb 2.115 ± 0.229 1.600 2.200 Iron Fe 0.136 ± 0.057 0.000 0.300 Tin Sn 0.000 ± 0.137 0.000 0.300 Nickel Ni 0.000 ± 0.065 0.000 0.100 Aluminium Al 0.000 0.050
Component: Cast Body
Bauteil: GusskörperComponent: Cast Body
Element % ± 2σ Min Max Kupfer Cu 58,703 ± 1,262 57,000 60,000 Zink Zn 38,663 ± 1,106 37,000 41,500 Blei Pb 2,176 ± 0,405 1,600 2,200 Eisen Fe 0,247 ± 0,124 0,000 0,300 Nickel Ni 0,210 ± 0,111 0,000 0,100 Zinn Sn 0,000 ± 0,336 0,000 0,300 Aluminium Al 0,000 0,050Element % ± 2σ Min Max Copper Cu 58.703 ± 1.262 57.000 60.000 Zinc Zn 38.663 ± 1.106 37.000 41.500 Lead Pb 2.176 ± 0.405 1.600 2.200 Iron Fe 0.247 ± 0.124 0.000 0.300 Nickel Ni 0.210 ± 0.111 0.000 0.100 Tin Sn 0.000 ± 0.336 0.000 0.300 Aluminium Al 0.000 0.050
Compliance and Material Information
Der Nachweis über die Eignung in Trinkwasserinstallationen nach Trinkwasserverordnung (TrinkwV 2001) ist somit erbracht. Das geprüfte Material entspricht den Vorgaben des Umweltbundesamtes bezüglich der „Bewertungsgrundlagen für metallene Werkstoffe im Kontakt mit Trinkwasser“- UBA- Positivliste. Der Werkstoff erfüllt laut Umweltbundesamt die Norm DIN 50930-6, die Aussagen bezüglich der Korrosionsbeständigkeit darlegt.The verification of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is therefore provided. The tested material complies with the requirements of the German Environment Agency regarding the "Evaluation Basis for Metallic Materials in Contact with Drinking Water" - UBA positive list. According to the German Environment Agency, the material meets the DIN 50930-6 standard, which provides information on corrosion resistance.
Werkstoff: CW617N (CuZn40Pb2)Material: CW617N (CuZn40Pb2)
Signatures and Additional Information
Olaf Manusch GeschäftsführerOlaf Manusch Managing Director
Hildesheim, 26. Oktober 2022Hildesheim, October 26, 2022
pra. Marc Manusch Leitung Technik & Qualitätswesenpra. Marc Manusch Head of Technology & Quality Assurance
Umweltbundesamt: „Bewertungsgrundlage für metallene Werkstoffe im Kontakt mit Trinkwasser“, (abgerufen am 26.10.2022).German Environment Agency: "Evaluation basis for metallic materials in contact with drinking water", (accessed on 26.10.2022).
Analysis Reports - PGWABNX-B - Version 1
General Information
Manufacturer PaulGurkes GmbH Klingenbergstr .12 31139 Hildesheim
Product Name Wall Connection Elbow Nostalgia Brass Bronze Hose Connection
Component: Connection Thread
Analysis Report XL2-99147
Measurement Number 1307
Mode Alloys
Measurement Duration 6.0s
Time 01.06.2007 00:19:18
Manufacturer Number wabnx - b - gewinde
User Login Marc Manusch
Material Suggestion CW617N_CuZn40Pb2
Element Analysis - Connection Thread
Element %
Copper Cu 58.919 ± 0.717 (57.000 - 60.000)
Zinc Zn 38.828 ± 0.629 (37.000 - 41.500)
Lead Pb 2.115 ± 0.229 (1.600 - 2.200)
Iron Fe 0.136 ± 0.057 (0.000 - 0.300)
Tin Sn 0.000 ± 0.137 (0.000 - 0.300)
Nickel Ni 0.000 ± 0.065 (0.000 - 0.100)
Aluminium Al 0.000 (Max 0.050)
Component: Cast Body
Analysis Report XL2-99147
Measurement Number 1312
Mode Alloys
Measurement Duration 2.6s
Time 01.06.2007 00:24:38
Manufacturer Number wabnx - b - guss
User Login Marc Manusch
Material Suggestion CW617N_CuZn40Pb2
Element Analysis - Cast Body
Element %
Copper Cu 58.703 ± 1.262 (57.000 - 60.000)
Zinc Zn 38.663 ± 1.106 (37.000 - 41.500)
Lead Pb 2.176 ± 0.405 (1.600 - 2.200)
Iron Fe 0.247 ± 0.124 (0.000 - 0.300)
Nickel Ni 0.210 ± 0.111 (0.000 - 0.100)
Tin Sn 0.000 ± 0.336 (0.000 - 0.300)
Aluminium Al 0.000 (Max 0.050)
Analysis Report
The sample was tested by X-ray fluorescence analysis and produced the following measurement result. The sample was tested by X-ray fluorescence analysis and produced the following measurement result.
The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided. The evidence of suitability in drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) has thus been provided.
The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment Criteria for Metallic Materials in Contact with Drinking Water" - UBA Positive List. The tested material complies with the requirements of the Federal Environment Agency regarding "Assessment Criteria for Metallic Materials in Contact with Drinking Water" - UBA Positive List.
The material complies with DIN 50930-6 according to the Federal Environment Agency, which provides information on corrosion resistance. The material complies with DIN 50930-6 according to the Federal Environment Agency, which provides information on corrosion resistance.
Material: CW617N (CuZn40Pb2) Material: CW617N (CuZn40Pb2)
Report Number: #2022
Analysis Reports - PGWABNX-B - Version 1
Analysis Report
German The sample was tested using X-ray fluorescence analysis and produced the following measurement results. The proof of suitability for drinking water installations according to the Drinking Water Ordinance (TrinkwV 2001) is thus provided. The tested material complies with the Federal Environment Agency requirements regarding "Evaluation criteria for metallic materials in contact with drinking water" - UBA positive list. According to the Federal Environment Agency, the material meets the DIN 50930-6 standard, which presents statements on corrosion resistance.
Material
German CW614N (CuZn39Pb3) + CW617N (CuZn40Pb2)
Report Number
German #2022-1320 + 1322
Manufacturer Number
German PGWABNX (-AR/-ARB)
EAN
German 4250914817676 / 4250914817669
Component: Cast Body
German Analysis Report XL2-99147
Measurement Number: 1320
Mode: Alloys
Measurement Duration: 9.1s
Time: 01.06.2007 00:27:14
Manufacturer Number: wabnx - thread
User Login: Marc Manusch
Material Suggestion: CW614N_CuZn39Pb3
Element%± 2σMinMax
Copper Cu59.426± 0.59257.00062.000
Zinc Zn37.609± 0.51233.50041.000
Lead Pb2.555± 0.2052.5003.500
Iron Fe0.214± 0.0550.0000.500
Tin Sn0.139± 0.0850.0000.300
Nickel Ni0.055± 0.0420.0000.200
Component: Connection Thread
German Analysis Report XL2-99147
Measurement Number: 1322
Mode: Alloys
Measurement Duration: 2.8s
Time: 01.06.2007 00:30:44
Manufacturer Number: wabnx - cast
User Login: Marc Manusch
Material Suggestion: CW617N_CuZn40Pb2
Element%± 2σMinMax
Copper Cu59.832± 1.35057.00060.000
Zinc Zn37.729± 1.14537.00041.500
Lead Pb2.155± 0.4151.6002.200
Iron Fe0.283± 0.1340.0000.300
Tin Sn0.000± 0.4000.0000.300
Nickel Ni0.000± 0.1130.0000.100
Aluminium Al0.0000.050
Publisher
German PaulGurkes GmbH
Klingenbergstr. 12
31139 Hildesheim
Approval
German Olaf Manusch - Managing Director
ppa. Marc Manusch - Head of Technical and Quality Management
Hildesheim, October 26, 2022

PGMW5-B

[pdf] PGMW5_Anordnungsplan
Title
Component List

[PDF] Allgemeine Pflegehinweise
Colour: Brass

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...

Loading 3D model...

Mouse: Rotate | Scroll: Zoom | Right-click: Pan Finger: Rotate | Pinch: Zoom | Two fingers: Pan